Description

APC NetShelter Rack PDU Advanced, Metered Outlet, 3PH, 22.1kW 400V 32A or 17.3kW 415V 30A, 48 Outlets, IEC309, Metered, Metered-by-outlet, 0U, Three-phase, Rackmount, Vertical, Black

APC NetShelter Rack PDU Advanced provide reliable power distribution to IT Equipment within server and/or networking racks. Outlet and PDU level power metering for power visibility and notification of potential overload. 4-in-1 combination outlets which can be used as either C13, C19, C15, or C21 outlets provide unparreled deployment flexibility. Maximum outlet density with 48 outlets in a 2.2 wide form factor. Outlets on the PDUs are color coded and/or labeled by breaker and input phase on 3 phase models to simplify deployment. Provides an alternating phase design whereby each of the 3 phases are organized into small outlet groups which alternate from top to bottom of the PDU to facilitate better power cord management and promote better load balancing. Power Sharing allows PDUs cascaded together via 2 ethernet ports enable an Network Management Card to continue functioning in the event of an AC power loss. No interruption in Network communication, sensors operation, and alarm traps. Live Swap Network Management Card (NMC) which can be replaced without powering down the PDU or connected devices to minimize downtime in the unlikely event of an NMC power event. Rated and approved to operate up to 60C (140F) at full load ensures reliability and availability even in today's high density deployments. Gigabit ethernet to enhance and standardize network connectivity across all assets in the data center. A second ethernet port (10/100) is available to allow cascading to other PDUs, connect to a 2nd private network, or provide network redundancy. 1% metering accuracy for the peace of mind to use NetShelter Rack PDU Advanced to bill based on power usage. In addition, the higher level of accuracy ensures the most precise measures for capacity planning and threshold alarm monitoring. Two environmental sensor ports allow for optional sensors (sold separately) to be connected. For data center deployments across multiple regions, these PDUs are both UL and CE rated providing one PDU that can be used globally to simplify and standardize deployment.

Specifications

BrandAPC
Manufacturer part no.APDU10350MO
Our part no.CF77948
EAN0731304439738
CategoryDocks, Bags & Racks › Racks & Cabinets
Weight0 kg
Design
PDU typesMetered, Metered-by-outlet
TypeThree-phase
Form factorRackmount
Rack capacity0U
MountingVertical
Product colourBlack
DisplayLCD
On/off switchYes
Regulatory ApprovalsCE, CSA C22.2 No 62368-1, EN 62368-1, FCC part 15 subpart B, UKCA, UL 62368-1
Ports & interfaces
AC outlets quantity48 AC outlet(s)
Power plugIEC 60309
AC outlet typesC13 coupler, C15 coupler, C19 coupler, C21 coupler
Ethernet LAN (RJ-45) ports2
USB ports quantity1
Features
Daisy chainYes
Reset buttonYes
LED indicatorsActivity, Network, Power
Colour-coded outletsYes
Cable length1.8 m
Security algorithms128-bit AES, 192-bit AES, 256-bit AES, DES, MD5, SNMP, SNMPv2, SNMPv3
Password protectionYes
Compatible productsCompatible with most NetShelter SX enclosures and third-party racks
Management features
MonitoringCurrent, Humidity, Power, Temperature, Voltage
Outlet controlLock-out, Recycle, Turn off, Turn on
Firmware upgradeableYes
Firmware upgradeable viaNetwork, USB
Power
Nominal input voltage400 V
AC input frequency50 - 60 Hz
Maximum current32 A
Nominal output voltage230 V
Load capacity22100 VA
Number of phases3
Power protection featuresOverload
Maximum power22100 W
Surge protectionYes
Certificates
Compliance certificatesRoHS
Operational conditions
Operating temperature (T-T)-5 - 60 °C
Storage temperature (T-T)-25 - 65 °C
Operating relative humidity (H-H)5 - 95%
Storage relative humidity (H-H)5 - 95%
Operating altitude0 - 3048 m
Non-operating altitude0 - 15240 m
Operating temperature (T-T)23 - 140 °F
Weight & dimensions
Width56 mm
Depth75 mm
Height1780 mm
Weight9.6 kg
Packaging data
Package weight12.6 kg
Package width262 mm
Package depth132 mm
Package height1980 mm
Logistics data
Total carbon footprint (kg of CO2e)16222.19
APC NetShelter Rack PDU Advanced, Metered Outlet, 3PH, 22.1kW 400V 32A or 17.3kW 415V 30A, 48 Outlets, IEC309 | Iconic Store